Please wait

Your message is being sent

An error occurred

Column ID mm
Column OD mm
Film thickness µm
Int. diam. mm
Length m
Outer diam. mm
Temp. range °C
Type
Optima® 624 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 3.0
Optima® 624 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 3.0
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 8 variants6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneUSP G43medium polar phaserecommended for environmental analysessimilar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°C
€730,00
Optima® 624 LB capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 1.8
Optima® 624 LB capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 1.8
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 2 variants6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneUSP G 43medium polar phaselow bleed columns for halogenated hydrocarbons, volatiles, aromatic compounds, solvents etc.similar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°C
€1.210,00
Optima® FFAP capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
Optima® FFAP capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 14 variantspolyethylene glycol 2-nitroterephthalateclose equivalent USP G25 / G35polar phaserecommended for FAME, free carboxylic acidssimilar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukolfor columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp.
€1.060,00
Optima® WAX capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 1.00
Optima® WAX capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 1.00
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 15 variantspolyethylene glycol 20000 daltonsUSP G16polar phaserecommended for solvent analysis and alcoholssuitable for aqueous solutionssimilar phases: Premabond® CW 20 M , DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax, 007-CW, BP20, AT-Wax, ZB-WaxMax. temperature for isothermal operation 240°C, max. temperature for short isotherms in a temperature programme: 250°C,for 0.53 mm ID columns the max. temperatures are 220 and 240°C, resp.
€730,00

Our website uses cookies.
Both we and our third-party partners use cookies. Some are strictly necessary for the site to function, but there are also optional cookies.

Necessary and functional cookies are always on. If you click "accept all cookies", you also accept the optional cookies. You can choose which cookies you want to enable via "set preferences".

Our website uses cookies.
What are cookies? What cookies do we use and why? Read more in our cookie policy

Necessary cookies

Cookies that are indispensable for your visit to the Website and the correct use thereof

Functional cookies

Cookies that make it easier and more pleasant for you to visit the Website, for example by personalising your browsing experience.

Performance cookies

Cookies that collect information about your use of the Website in order to improve the content of the Website and adapt it to the wishes of the User.

Third-party cookies

Cookies placed by third parties who offer their own services via the Website, such as social media, advertisements or video services.