Optima® 624 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 3.0
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 8 variants6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneUSP G43medium polar phaserecommended for environmental analysessimilar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°COptima® 624 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 3.0
€730,00
Optima® 624 LB capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 1.8
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 2 variants6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneUSP G 43medium polar phaselow bleed columns for halogenated hydrocarbons, volatiles, aromatic compounds, solvents etc.similar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°COptima® 624 LB capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 1.8
€1.210,00
Optima® FFAP capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 14 variantspolyethylene glycol 2-nitroterephthalateclose equivalent USP G25 / G35polar phaserecommended for FAME, free carboxylic acidssimilar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukolfor columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp.Optima® FFAP capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
€1.060,00
Optima® WAX capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 1.00
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 15 variantspolyethylene glycol 20000 daltonsUSP G16polar phaserecommended for solvent analysis and alcoholssuitable for aqueous solutionssimilar phases: Premabond® CW 20 M , DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax, 007-CW, BP20, AT-Wax, ZB-WaxMax. temperature for isothermal operation 240°C, max. temperature for short isotherms in a temperature programme: 250°C,for 0.53 mm ID columns the max. temperatures are 220 and 240°C, resp.Optima® WAX capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 1.00
€730,00
Copyright © 2026 - Achrom nv - BE 0445.025.508 | General terms | Cookiebeleid | Privacybeleid | Handcrafted by CrayonCru®