Even geduld

Uw bericht wordt verstuurd

Er is een fout opgetreden

Column ID mm
Column OD mm
Film thickness µm
Int. diam. mm
Length m
Outer diam. mm
Temp. range °C
Type
GC Capillary columns HYDRODEX β-6TBDM | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Length m: 25
GC Capillary columns HYDRODEX β-6TBDM | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Length m: 25
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 2 variantenHeptakis-(2,3-di-O-methyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for γ-lactones, cyclopentanones, terpenes, esters, tartrates.Max. temperature for isothermal operation: 230°CMax. temperature for short isotherms in a temperature programme: 250°C
€1.275,00
GC Capillary columns HYDRODEX β-TBDAC | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Length m: 50
GC Capillary columns HYDRODEX β-TBDAC | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Length m: 50
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 2 variantenHeptakis-(2,3-di-O-acetyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for alcohols, esters, ketones, aldehydes, δ-lactones.Max. temperature for isothermal operation: 220°CMax. temperature for short isotherms in a temperature programme: 240°C
€1.915,00
GC Capillary columns LIPODEX® E | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Length m: 50
GC Capillary columns LIPODEX® E | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Length m: 50
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 2 variantenOctakis-(2,6-di-O-pentyl-3-O-butyryl)-γ-cyclodextrin. Recommended for α-amino acids, α- and β-hydroxycarboxylic acid esters, alcohols (TFA), diols (TFA), ketones, pheromones (cyclic acetals), amines, alkyl halides, lactones.Max. temperature for isothermal operation: 200°CMax. temperature for short isotherms in a temperature programme: 220°C
€2.010,00
OPTIMA® 1 high performance capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Length m: 30
OPTIMA® 1 high performance capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Length m: 30
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 51 varianten100% dimethylpolysiloxanenonpolar phase separation of components according to boiling points thick film columns ≥3µm film are especially recommended for solvent analysis.Similar phases: Permabond® SE-30, OV-1, DB-1, SE-30, HP-1, SPB-1, CP-Sil 5 CB, Rtx-1, 007-1, BP1, MDN-1, AT-1, ZB-1, OV-101.For columns with 0.25 to 0.32mm ID and films
€730,00
OPTIMA® 1 MS Accent ultra-low bleed capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
OPTIMA® 1 MS Accent ultra-low bleed capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 8 varianten100 % dimethylpolysiloxanenonpolar phase with ultra-low bleeding, ideal for ion trap and quadrupol MS detectors increased sensitivity due to an unmatched low background level perfect inertness for basic compoundssolvent rinsing for removal of impurities applicableapplication areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analysessimilar phases: Ultra-1, DB-1 MS, HP-1 MS, Rtx-1 MS, Equity™1, AT-1 MS, VF-1 MS, CP-Sil 5 CB MSmax. temperature for isothermal operation 340 °C, max. temperature for short isotherms in a temperature programme 360 °C
€1.510,00
Optima® 17 capillary columns for GC | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Film thickness µm: 0.50
Optima® 17 capillary columns for GC | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Film thickness µm: 0.50
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 28 variantenphenylmethylpolysiloxane (50 % phenyl)medium polar phasepreferred applications: steroids, pesticides, drug analysesUSP G3similar phases: OV-17, DB-17, HP50+, HP17, SPB-50, SP-2250, Rtx-50, CP-Sil 24 CB, 007-17, ZB50 max. temperature for isothermal operation: 320°C, max. temperature for short isotherms in a temperature programme: 340°C, for 0.53mm ID columns the max. temperatures are 300 and 320°C, resp.
€980,00
Optima® 1701 capillary columns for GC | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Film thickness µm: 0.25
Optima® 1701 capillary columns for GC | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Film thickness µm: 0.25
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 28 varianten14 % Cyanopropyl-phenyl - 86 % Dimethylpolysiloxane USP G46medium polar phasespecial selectivity due to high cyanopropyl contentreference column for structure identification, e.g. in combination with Optima 5film thickness 1 µm for solvent analysessimilar phases: OV-1701, DB-1701, CP?Sil 19 CB, HP-1701, Rtx-1701, SPB-1701, 007-1701, BP10, ZB-1701max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°Cfor 0.53mm ID columns the max. temperatures are 280 and 300°C, resp.
€590,00
OPTIMA® 225 capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
OPTIMA® 225 capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 7 varianten50% cyanopropylmethyl - 50% phenylmethylpolysiloxaneUSP G7 / G19middle polar phaserecommended for fatty acid analysessimilar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, 007-225, BP225max. temperature for isothermal operation: 260°C, max. temperature for short isotherms in a temperature programme: 280°C
€1.125,00
Optima® 5 Amine GC capillary columns for amine separation | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Film thickness µm: 1.00
Optima® 5 Amine GC capillary columns for amine separation | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Film thickness µm: 1.00
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 3 variantenespecially deactivated for the analysis of polyfunctional amines such as ethanolamines, amino-functionalised diols and similar compounds, which are important base materials in industrial chemistry, and shows strong tailing on standard-deactivated columns; similar phases: Rtx-5 Amine, PTA-5; USP G27 / G36; improved linearity for analyses of active components at trace levels: no amine absorptions even for aliphatic and aromatic amines at concentrations of 100 pg/peak; tested with the Optima® Amine test mixture, which among others also contains diethanolamine and propanol-pyridine (this test mixture is supplied with each column). Max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°C.
€680,00
OPTIMA® 5 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Length m: 50
OPTIMA® 5 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Length m: 50
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 58 varianten5% phenyl - 95% dimethylpolysiloxane USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films
€1.130,00
OPTIMA® 5 MS Accent capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.50
OPTIMA® 5 MS Accent capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.50
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 11 variantensilarylene phaseWith polarity similar to a 5 % diphenyl -95 % dimethylpolysiloxane phase.USP G27, G36Lowest column bleed, nonpolar phase, ideal for ion trap and quadrupol MS detectors solvent rinsing for removal of impurities applicableApplication areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analysessimilar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MSMax. temperature for isothermal operation: 340 °C,Max. temperature for short isotherms in a temperature programme: 360 °Cfor cloumns with film thicknesses > 5.5 µm the max. temperatures are 320 and 340 °C
€815,00
OPTIMA® 5 MS capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Length m: 50
OPTIMA® 5 MS capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Length m: 50
Merk: Macherey-Nagel GmbH & Co. KGBeschikbaar in 10 varianten5% diphenyl - 95% dimethylpolysiloxanenonpolar phase with low bleeding, deal for GC/MS and ECD applications and general analyses at trace level perfect inertness for basic compounds.Similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS.max. temperature for isothermal operation: 340°C, max. temperature for short isotherms in a temperature programme: 360 °C
€1.210,00

Onze website maakt gebruik van cookies.
Zowel wij en onze derde partij partners maken gebruik van cookies. Sommige zijn strikt noodzakelijk om de site te laten functioneren, maar er bestaan ook optionele cookies.

De noodzakelijke en functionele cookies staan altijd aan. Als je op "alle cookies aanvaarden" klikt accepteer je ook de optionele cookies. Je kan zelf kiezen welke cookies je aan wil zetten via "voorkeuren instellen".

Onze website maakt gebruik van cookies.
Wat zijn cookies? Welke cookies gebruiken we en waarom? Lees meer in ons cookiebeleid

Noodzakelijke cookies

Cookies die onontbeerlijk zijn voor uw bezoek aan de Website en het correct gebruik daarvan

Functionele cookies

Cookies die uw bezoek aan de Website vergemakkelijken en aangenamer maken, onder meer door uw surfervaring te personaliseren.

Performantie cookies

Cookies die informatie verzamelen over uw gebruik van de Website met de bedoeling de inhoud van de Website te verbeteren en aan te passen aan de wensen van de Gebruiker.

Derde partij cookies

Cookies die geplaatst worden door derden die eigen diensten aanbieden via de Website zoals bijvoorbeeld social media, advertenties of videodiensten.