Even geduld

Uw bericht wordt verstuurd

Er is een fout opgetreden

EUKITT® UV mounting medium 100 ml with UV curing lamp system, for microscopy (no dan. goods)
EUKITT® UV mounting medium 100 ml with UV curing lamp system, for microscopy (no dan. goods)
€65,48
EUKITT®Mounting medium | Type : EUKITT®UV R, Capacity ml : 100, Refractive index n (20 °C) : 1.48
EUKITT®Mounting medium | Type : EUKITT®UV R, Capacity ml : 100, Refractive index n (20 °C) : 1.48
Merk: ORSAtec GmbHBeschikbaar in 5 variantenEUKITT® mounting media are characterized by fast curing, crystal-clear optics, low fluorescence, ideal refractive index, good fluidity and low shrinkage. The preparations are stable over many years without cracking and discoloration. EUKITT® mounting media are colorless and do not change shape, structure or color of the material to be examined. No self-fluorescence under UV light! Delivered in wide neck, unbreakable aluminium bottles.EUKITT®: Gold-standard mounting medium. Particularly preferred for use in coverslippers. EUKITT® resists heat, cold (-17 °C), humidity, daylight and UV light and preserves the original preparations for an unlimited period. Drying time: 20 minutes.EUKITT® neo Spezial: Fast drying, xylene free mounting medium. Can be directly applied on EtOH or i-PrOH. Washing with xylene can be omitted. Modern formulation approach using a sustainable, renewable raw material as a solvent. Pleasant odour. Drying time: 15 minutes.EUKITT® UV R: Curing with a single click. Mounting medium which is very quickly cured by UV-light. Only 50% of the amount of standard mounting media are needed. EUKITT® UV R can be directly applied on EtOH or i-PrOH and does not present any health risks. Suitable for all tissue types. Curing time: 10 to 30 seconds.
€35,55
EUKITT®Mounting medium | Type: EUKITT®, Capacity ml: 100, Refractive index n (20 °C): 1.49
EUKITT®Mounting medium | Type: EUKITT®, Capacity ml: 100, Refractive index n (20 °C): 1.49
Merk: ORSAtec GmbHBeschikbaar in 5 variantenEUKITT® mounting media are characterized by fast curing, crystal-clear optics, low fluorescence, ideal refractive index, good fluidity and low shrinkage. The preparations are stable over many years without cracking and discoloration. EUKITT® mounting media are colorless and do not change shape, structure or color of the material to be examined. No self-fluorescence under UV light! Delivered in wide neck, unbreakable aluminium bottles.EUKITT®: Gold-standard mounting medium. Particularly preferred for use in coverslippers. EUKITT® resists heat, cold (-17 °C), humidity, daylight and UV light and preserves the original preparations for an unlimited period. Drying time: 20 minutes.EUKITT® neo Spezial: Fast drying, xylene free mounting medium. Can be directly applied on EtOH or i-PrOH. Washing with xylene can be omitted. Modern formulation approach using a sustainable, renewable raw material as a solvent. Pleasant odour. Drying time: 15 minutes.EUKITT® UV R: Curing with a single click. Mounting medium which is very quickly cured by UV-light. Only 50% of the amount of standard mounting media are needed. EUKITT® UV R can be directly applied on EtOH or i-PrOH and does not present any health risks. Suitable for all tissue types. Curing time: 10 to 30 seconds.
€27,50
EUKITT®Mounting medium | Type: EUKITT®, Capacity ml: 500, Refractive index n (20 °C): 1.49
EUKITT®Mounting medium | Type: EUKITT®, Capacity ml: 500, Refractive index n (20 °C): 1.49
Merk: ORSAtec GmbHBeschikbaar in 5 variantenEUKITT® mounting media are characterized by fast curing, crystal-clear optics, low fluorescence, ideal refractive index, good fluidity and low shrinkage. The preparations are stable over many years without cracking and discoloration. EUKITT® mounting media are colorless and do not change shape, structure or color of the material to be examined. No self-fluorescence under UV light! Delivered in wide neck, unbreakable aluminium bottles.EUKITT®: Gold-standard mounting medium. Particularly preferred for use in coverslippers. EUKITT® resists heat, cold (-17 °C), humidity, daylight and UV light and preserves the original preparations for an unlimited period. Drying time: 20 minutes.EUKITT® neo Spezial: Fast drying, xylene free mounting medium. Can be directly applied on EtOH or i-PrOH. Washing with xylene can be omitted. Modern formulation approach using a sustainable, renewable raw material as a solvent. Pleasant odour. Drying time: 15 minutes.EUKITT® UV R: Curing with a single click. Mounting medium which is very quickly cured by UV-light. Only 50% of the amount of standard mounting media are needed. EUKITT® UV R can be directly applied on EtOH or i-PrOH and does not present any health risks. Suitable for all tissue types. Curing time: 10 to 30 seconds.
€60,55
EUKITT®Mounting medium | Type: EUKITT®neo spezial, Capacity ml: 100, Refractive index n (20 °C): 1.48
EUKITT®Mounting medium | Type: EUKITT®neo spezial, Capacity ml: 100, Refractive index n (20 °C): 1.48
Merk: ORSAtec GmbHBeschikbaar in 5 variantenEUKITT® mounting media are characterized by fast curing, crystal-clear optics, low fluorescence, ideal refractive index, good fluidity and low shrinkage. The preparations are stable over many years without cracking and discoloration. EUKITT® mounting media are colorless and do not change shape, structure or color of the material to be examined. No self-fluorescence under UV light! Delivered in wide neck, unbreakable aluminium bottles.EUKITT®: Gold-standard mounting medium. Particularly preferred for use in coverslippers. EUKITT® resists heat, cold (-17 °C), humidity, daylight and UV light and preserves the original preparations for an unlimited period. Drying time: 20 minutes.EUKITT® neo Spezial: Fast drying, xylene free mounting medium. Can be directly applied on EtOH or i-PrOH. Washing with xylene can be omitted. Modern formulation approach using a sustainable, renewable raw material as a solvent. Pleasant odour. Drying time: 15 minutes.EUKITT® UV R: Curing with a single click. Mounting medium which is very quickly cured by UV-light. Only 50% of the amount of standard mounting media are needed. EUKITT® UV R can be directly applied on EtOH or i-PrOH and does not present any health risks. Suitable for all tissue types. Curing time: 10 to 30 seconds.
€34,10
EUKITT®Mounting medium | Type: EUKITT®neo spezial, Capacity ml: 500, Refractive index n (20 °C): 1.48
EUKITT®Mounting medium | Type: EUKITT®neo spezial, Capacity ml: 500, Refractive index n (20 °C): 1.48
Merk: ORSAtec GmbHBeschikbaar in 5 variantenEUKITT® mounting media are characterized by fast curing, crystal-clear optics, low fluorescence, ideal refractive index, good fluidity and low shrinkage. The preparations are stable over many years without cracking and discoloration. EUKITT® mounting media are colorless and do not change shape, structure or color of the material to be examined. No self-fluorescence under UV light! Delivered in wide neck, unbreakable aluminium bottles.EUKITT®: Gold-standard mounting medium. Particularly preferred for use in coverslippers. EUKITT® resists heat, cold (-17 °C), humidity, daylight and UV light and preserves the original preparations for an unlimited period. Drying time: 20 minutes.EUKITT® neo Spezial: Fast drying, xylene free mounting medium. Can be directly applied on EtOH or i-PrOH. Washing with xylene can be omitted. Modern formulation approach using a sustainable, renewable raw material as a solvent. Pleasant odour. Drying time: 15 minutes.EUKITT® UV R: Curing with a single click. Mounting medium which is very quickly cured by UV-light. Only 50% of the amount of standard mounting media are needed. EUKITT® UV R can be directly applied on EtOH or i-PrOH and does not present any health risks. Suitable for all tissue types. Curing time: 10 to 30 seconds.
€72,60
Histological staining solutions | Type : HTX Mayer, 1 Liter
Histological staining solutions | Type : HTX Mayer, 1 Liter
Merk: ORSAtec GmbHBeschikbaar in 3 variantenStains are delivered in 1000 ml bottles. Each bottle is sufficient for 1500 up to 2500 specimens. They can be used for clinical diagnostics.Harris' hematoxylin solution (Papanicolaou's solution 1a): The cytological staining technique developed by Papanicolaou is still the standard method in cancer and hormone cycle diagnosis. By using the classical Harris' hematoxylin solution (Papanicolaou's solution 1a), excellent nuclear staining can be achieved in 3 to 5 minutes. Nuclei are stained blue, dark violet to black. Densitiy (20 °C): 1.04 g/cm3. pH value (20 °C): 2.3 to 2.8. C.I. 75290: 5,3 g/l. Al2(SO4)3 x 18 H2O: 67 g/lMayer's hemalum solution: This solution does not need to be filtrated prior use and the dye is oxidized in a controlled manner, which renders the results robust and allows a brilliant differentiation of the stained structures. Nuclei are intensive blue, cytoplasm is grey-blue. Density (20 °C): 1,05 g/cm3. pH value (20 °C): 1.8 to 2.2. C.I. 75290: 4.4 g/l. Al2(SO4)3 x 18 H2O: 28 g/l. C6H8O7 x H2O: 0.5 g/l0.2% EOSIN Y solution alcoholic: A ready-to-use solution that can be used for routine staining in the hematoxylin-eosin staining process (H&E) of sample material of human origin. Due to the hematoxylin solution, the nuclei will appear blue to dark violet in color and the Eosin Y solution will stain the cytoplasma and intercellular substances red-orange.
€41,03
Histological staining solutions | Type: EOSIN (0.2% alkoholic), 1 Liter
Histological staining solutions | Type: EOSIN (0.2% alkoholic), 1 Liter
Merk: ORSAtec GmbHBeschikbaar in 3 variantenStains are delivered in 1000 ml bottles. Each bottle is sufficient for 1500 up to 2500 specimens. They can be used for clinical diagnostics.Harris' hematoxylin solution (Papanicolaou's solution 1a): The cytological staining technique developed by Papanicolaou is still the standard method in cancer and hormone cycle diagnosis. By using the classical Harris' hematoxylin solution (Papanicolaou's solution 1a), excellent nuclear staining can be achieved in 3 to 5 minutes. Nuclei are stained blue, dark violet to black. Densitiy (20 °C): 1.04 g/cm3. pH value (20 °C): 2.3 to 2.8. C.I. 75290: 5,3 g/l. Al2(SO4)3 x 18 H2O: 67 g/lMayer's hemalum solution: This solution does not need to be filtrated prior use and the dye is oxidized in a controlled manner, which renders the results robust and allows a brilliant differentiation of the stained structures. Nuclei are intensive blue, cytoplasm is grey-blue. Density (20 °C): 1,05 g/cm3. pH value (20 °C): 1.8 to 2.2. C.I. 75290: 4.4 g/l. Al2(SO4)3 x 18 H2O: 28 g/l. C6H8O7 x H2O: 0.5 g/l0.2% EOSIN Y solution alcoholic: A ready-to-use solution that can be used for routine staining in the hematoxylin-eosin staining process (H&E) of sample material of human origin. Due to the hematoxylin solution, the nuclei will appear blue to dark violet in color and the Eosin Y solution will stain the cytoplasma and intercellular substances red-orange.
€22,47
Histological staining solutions | Type: HTX Harris, 1 Liter
Histological staining solutions | Type: HTX Harris, 1 Liter
Merk: ORSAtec GmbHBeschikbaar in 3 variantenStains are delivered in 1000 ml bottles. Each bottle is sufficient for 1500 up to 2500 specimens. They can be used for clinical diagnostics.Harris' hematoxylin solution (Papanicolaou's solution 1a): The cytological staining technique developed by Papanicolaou is still the standard method in cancer and hormone cycle diagnosis. By using the classical Harris' hematoxylin solution (Papanicolaou's solution 1a), excellent nuclear staining can be achieved in 3 to 5 minutes. Nuclei are stained blue, dark violet to black. Densitiy (20 °C): 1.04 g/cm3. pH value (20 °C): 2.3 to 2.8. C.I. 75290: 5,3 g/l. Al2(SO4)3 x 18 H2O: 67 g/lMayer's hemalum solution: This solution does not need to be filtrated prior use and the dye is oxidized in a controlled manner, which renders the results robust and allows a brilliant differentiation of the stained structures. Nuclei are intensive blue, cytoplasm is grey-blue. Density (20 °C): 1,05 g/cm3. pH value (20 °C): 1.8 to 2.2. C.I. 75290: 4.4 g/l. Al2(SO4)3 x 18 H2O: 28 g/l. C6H8O7 x H2O: 0.5 g/l0.2% EOSIN Y solution alcoholic: A ready-to-use solution that can be used for routine staining in the hematoxylin-eosin staining process (H&E) of sample material of human origin. Due to the hematoxylin solution, the nuclei will appear blue to dark violet in color and the Eosin Y solution will stain the cytoplasma and intercellular substances red-orange.
€42,53

Onze website maakt gebruik van cookies.
Zowel wij en onze derde partij partners maken gebruik van cookies. Sommige zijn strikt noodzakelijk om de site te laten functioneren, maar er bestaan ook optionele cookies.

De noodzakelijke en functionele cookies staan altijd aan. Als je op "alle cookies aanvaarden" klikt accepteer je ook de optionele cookies. Je kan zelf kiezen welke cookies je aan wil zetten via "voorkeuren instellen".

Onze website maakt gebruik van cookies.
Wat zijn cookies? Welke cookies gebruiken we en waarom? Lees meer in ons cookiebeleid

Noodzakelijke cookies

Cookies die onontbeerlijk zijn voor uw bezoek aan de Website en het correct gebruik daarvan

Functionele cookies

Cookies die uw bezoek aan de Website vergemakkelijken en aangenamer maken, onder meer door uw surfervaring te personaliseren.

Performantie cookies

Cookies die informatie verzamelen over uw gebruik van de Website met de bedoeling de inhoud van de Website te verbeteren en aan te passen aan de wensen van de Gebruiker.

Derde partij cookies

Cookies die geplaatst worden door derden die eigen diensten aanbieden via de Website zoals bijvoorbeeld social media, advertenties of videodiensten.