Even geduld

Uw bericht wordt verstuurd

Er is een fout opgetreden

Exhaust air system for MCS-models
Exhaust air system for MCS-models
€690,02
Handle for autoclave type KL-12-2
Handle for autoclave type KL-12-2
€11,25
Heating Element for MCS-203, 204 and VA-MSC
Heating Element for MCS-203, 204 and VA-MSC
€187,08
Laboratory autoclave LaM-4-20-ECZ-J 20 ltr. up to 4 bar, with heating, white enamelled
Laboratory autoclave LaM-4-20-ECZ-J 20 ltr. up to 4 bar, with heating, white enamelled
€3.864,97
Laboratory autoclave LaM-4-20-MCS-J 20 ltr., up to 4 bar, 142°C, autom. temperature, white enamelled
Laboratory autoclave LaM-4-20-MCS-J 20 ltr., up to 4 bar, 142°C, autom. temperature, white enamelled
€4.819,21
Laboratory autoclave LaS-4-20 20 ltr. up to 4 bar, without heating, black silitated
Laboratory autoclave LaS-4-20 20 ltr. up to 4 bar, without heating, black silitated
€2.421,61
Laboratory autoclaves with heating | Type: La-MCS-203, Pressure bar: 3, Temperature °C: 143
Laboratory autoclaves with heating | Type: La-MCS-203, Pressure bar: 3, Temperature °C: 143
Merk: Maschinenbau Wolf GmbHBeschikbaar in 5 variantenFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€5.940,48
Laboratory autoclaves with heating | Type: La-MCS-204, Pressure bar: 4, Temperature °C: 151
Laboratory autoclaves with heating | Type: La-MCS-204, Pressure bar: 4, Temperature °C: 151
Merk: Maschinenbau Wolf GmbHBeschikbaar in 5 variantenFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€6.044,20
Laboratory autoclaves with heating | Type: La-VA-MCS, Pressure bar: 4, Temperature °C: 151
Laboratory autoclaves with heating | Type: La-VA-MCS, Pressure bar: 4, Temperature °C: 151
Merk: Maschinenbau Wolf GmbHBeschikbaar in 5 variantenFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€6.846,68
Laboratory autoclaves with heating | Type: LaM-3-20-ECZ-J*, Pressure bar: 3, Temperature °C: 143
Laboratory autoclaves with heating | Type: LaM-3-20-ECZ-J*, Pressure bar: 3, Temperature °C: 143
Merk: Maschinenbau Wolf GmbHBeschikbaar in 5 variantenFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€3.697,93
Laboratory autoclaves with heating | Type: LaM-3-20-MCS-J, Pressure bar: 3, Temperature °C: 143
Laboratory autoclaves with heating | Type: LaM-3-20-MCS-J, Pressure bar: 3, Temperature °C: 143
Merk: Maschinenbau Wolf GmbHBeschikbaar in 5 variantenFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€4.664,17
Level insert type T 2, 2-parts 23 x 12 cm
Level insert type T 2, 2-parts 23 x 12 cm
€107,50

Onze website maakt gebruik van cookies.
Zowel wij en onze derde partij partners maken gebruik van cookies. Sommige zijn strikt noodzakelijk om de site te laten functioneren, maar er bestaan ook optionele cookies.

De noodzakelijke en functionele cookies staan altijd aan. Als je op "alle cookies aanvaarden" klikt accepteer je ook de optionele cookies. Je kan zelf kiezen welke cookies je aan wil zetten via "voorkeuren instellen".

Onze website maakt gebruik van cookies.
Wat zijn cookies? Welke cookies gebruiken we en waarom? Lees meer in ons cookiebeleid

Noodzakelijke cookies

Cookies die onontbeerlijk zijn voor uw bezoek aan de Website en het correct gebruik daarvan

Functionele cookies

Cookies die uw bezoek aan de Website vergemakkelijken en aangenamer maken, onder meer door uw surfervaring te personaliseren.

Performantie cookies

Cookies die informatie verzamelen over uw gebruik van de Website met de bedoeling de inhoud van de Website te verbeteren en aan te passen aan de wensen van de Gebruiker.

Derde partij cookies

Cookies die geplaatst worden door derden die eigen diensten aanbieden via de Website zoals bijvoorbeeld social media, advertenties of videodiensten.