Accessories for Thermal printer P 3002 | Type: RP 3001, Description: Printer paper, width 112 mm
Accessories for Thermal printer P 3002 | Type: RP 3001, Description: Printer paper, width 112 mm
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 2 varianten
€12,60
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 690-15, Cable m: 15
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 690-15, Cable m: 15
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€1.364,00
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 690-7, Cable m: 7
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 690-7, Cable m: 7
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€1.328,00
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 700-12, Cable m: 12
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 700-12, Cable m: 12
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€2.038,00
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 700-15, Cable m: 15
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 700-15, Cable m: 15
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€1.882,00
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 700-7, Cable m: 1.5
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 700-7, Cable m: 1.5
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€1.840,00
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 700-SO, Cable m: Freely selectable
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 700-SO, Cable m: Freely selectable
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€1.822,00
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 701-7, Cable m: 7
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic® 701-7, Cable m: 7
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€1.907,00
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic®701-15, Cable m: 15
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic®701-15, Cable m: 15
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€2.063,00
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic®701-SO, Cable m: Freely selectable
Analog electro-chemical D.O. sensors TriOxmatic® | Type: TriOxmatic®701-SO, Cable m: Freely selectable
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 9 variantenD.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
€1.960,00
Calibration and storage containers for oxygen sensors | Type: FDO® Check, Description: Test/calibration vessel FDO® 925
Calibration and storage containers for oxygen sensors | Type: FDO® Check, Description: Test/calibration vessel FDO® 925
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 5 variantenSensor-specific vessels to test, calibrate and store dissolved oxygen sensors (galvanized and optical).Easy handlingStandard conform calibrationPerfect transport protection
€206,00
Calibration and storage containers for oxygen sensors | Type: OxiCal® CX, Description: Storage/calibration container ConOx
Calibration and storage containers for oxygen sensors | Type: OxiCal® CX, Description: Storage/calibration container ConOx
Merk: Xylem Analytics Germany (WTW)Beschikbaar in 5 variantenSensor-specific vessels to test, calibrate and store dissolved oxygen sensors (galvanized and optical).Easy handlingStandard conform calibrationPerfect transport protection
€198,00

Onze website maakt gebruik van cookies.
Zowel wij en onze derde partij partners maken gebruik van cookies. Sommige zijn strikt noodzakelijk om de site te laten functioneren, maar er bestaan ook optionele cookies.

De noodzakelijke en functionele cookies staan altijd aan. Als je op "alle cookies aanvaarden" klikt accepteer je ook de optionele cookies. Je kan zelf kiezen welke cookies je aan wil zetten via "voorkeuren instellen".

Onze website maakt gebruik van cookies.
Wat zijn cookies? Welke cookies gebruiken we en waarom? Lees meer in ons cookiebeleid

Noodzakelijke cookies

Cookies die onontbeerlijk zijn voor uw bezoek aan de Website en het correct gebruik daarvan

Functionele cookies

Cookies die uw bezoek aan de Website vergemakkelijken en aangenamer maken, onder meer door uw surfervaring te personaliseren.

Performantie cookies

Cookies die informatie verzamelen over uw gebruik van de Website met de bedoeling de inhoud van de Website te verbeteren en aan te passen aan de wensen van de Gebruiker.

Derde partij cookies

Cookies die geplaatst worden door derden die eigen diensten aanbieden via de Website zoals bijvoorbeeld social media, advertenties of videodiensten.