Even geduld

Uw bericht wordt verstuurd

Er is een fout opgetreden

BOD-Measurement-System BD 600 | Type : Sensor Calibration Set, Description : for BSB/BOD Sensor
BOD-Measurement-System BD 600 | Type : Sensor Calibration Set, Description : for BSB/BOD Sensor
Merk: Tintometer GmbHBeschikbaar in 10 variantenBOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Scope of supply:BD 600, complete unit with 6 or 12* sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 or 12* sample bottles6 or 12* rubber gaskets6 or 12* magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualremote control
€67,60
BOD-Measurement-System BD 600 | Type: Kaliumhydroxid-Lösung, Description: 50 ml, 45 %
BOD-Measurement-System BD 600 | Type: Kaliumhydroxid-Lösung, Description: 50 ml, 45 %
Merk: Tintometer GmbHBeschikbaar in 10 variantenBOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Scope of supply:BD 600, complete unit with 6 or 12* sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 or 12* sample bottles6 or 12* rubber gaskets6 or 12* magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualremote control
€16,70
BOD-Measurement-System BD 600 | Type: Nitrification inhibitor (N-ATH), Description: liquid, bottle of 50 ml
BOD-Measurement-System BD 600 | Type: Nitrification inhibitor (N-ATH), Description: liquid, bottle of 50 ml
Merk: Tintometer GmbHBeschikbaar in 10 variantenBOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Scope of supply:BD 600, complete unit with 6 or 12* sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 or 12* sample bottles6 or 12* rubber gaskets6 or 12* magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualremote control
€26,10
BOD-Measurement-System BD 600 | Type: Rubber sleeve (4.5 cm)
BOD-Measurement-System BD 600 | Type: Rubber sleeve (4.5 cm)
Merk: Tintometer GmbHBeschikbaar in 10 variantenBOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Scope of supply:BD 600, complete unit with 6 or 12* sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 or 12* sample bottles6 or 12* rubber gaskets6 or 12* magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualremote control
€8,90
BOD-Measurement-System BD 600 | Type: Rubber sleeve (6.5 cm)
BOD-Measurement-System BD 600 | Type: Rubber sleeve (6.5 cm)
Merk: Tintometer GmbHBeschikbaar in 10 variantenBOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Scope of supply:BD 600, complete unit with 6 or 12* sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 or 12* sample bottles6 or 12* rubber gaskets6 or 12* magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualremote control
€8,90
Brush 20 cm
Brush 20 cm
€7,20
BSB sensor head oxidirect
BSB sensor head oxidirect
€236,60
Buffer tablets for Pocket Tester Lovibond® | Type: Buffer tablets pH 10, For: Buffer
Buffer tablets for Pocket Tester Lovibond® | Type: Buffer tablets pH 10, For: Buffer
Merk: Tintometer GmbHBeschikbaar in 3 varianten
€24,60
Buffer tablets for Pocket Tester Lovibond® | Type: Buffer tablets pH 4, For: Buffer
Buffer tablets for Pocket Tester Lovibond® | Type: Buffer tablets pH 4, For: Buffer
Merk: Tintometer GmbHBeschikbaar in 3 varianten
€24,60
Buffer tablets for Pocket Tester Lovibond® | Type: Buffer tablets pH 7, For: Buffer
Buffer tablets for Pocket Tester Lovibond® | Type: Buffer tablets pH 7, For: Buffer
Merk: Tintometer GmbHBeschikbaar in 3 varianten
€24,60
Calibration and Storage solutions for pH/Redox-Meter SD 305 pH | Description: Calibration solution Redox, 470 mV, 100 ml, NIST
Calibration and Storage solutions for pH/Redox-Meter SD 305 pH | Description: Calibration solution Redox, 470 mV, 100 ml, NIST
Merk: Tintometer GmbHBeschikbaar in 8 varianten
€15,10
Calibration and Storage solutions for pH/Redox-Meter SD 305 pH | Description: pH buffer solution 10.00 (25 °C) blue, 90 ml, NIST
Calibration and Storage solutions for pH/Redox-Meter SD 305 pH | Description: pH buffer solution 10.00 (25 °C) blue, 90 ml, NIST
Merk: Tintometer GmbHBeschikbaar in 8 varianten
€6,30

Onze website maakt gebruik van cookies.
Zowel wij en onze derde partij partners maken gebruik van cookies. Sommige zijn strikt noodzakelijk om de site te laten functioneren, maar er bestaan ook optionele cookies.

De noodzakelijke en functionele cookies staan altijd aan. Als je op "alle cookies aanvaarden" klikt accepteer je ook de optionele cookies. Je kan zelf kiezen welke cookies je aan wil zetten via "voorkeuren instellen".

Onze website maakt gebruik van cookies.
Wat zijn cookies? Welke cookies gebruiken we en waarom? Lees meer in ons cookiebeleid

Noodzakelijke cookies

Cookies die onontbeerlijk zijn voor uw bezoek aan de Website en het correct gebruik daarvan

Functionele cookies

Cookies die uw bezoek aan de Website vergemakkelijken en aangenamer maken, onder meer door uw surfervaring te personaliseren.

Performantie cookies

Cookies die informatie verzamelen over uw gebruik van de Website met de bedoeling de inhoud van de Website te verbeteren en aan te passen aan de wensen van de Gebruiker.

Derde partij cookies

Cookies die geplaatst worden door derden die eigen diensten aanbieden via de Website zoals bijvoorbeeld social media, advertenties of videodiensten.