Moisture Analyser HX/HS series | Type: HX204, max. load g: 200, Resolution g: 0.001
Moisture Analyser HX/HS series | Type: HX204, max. load g: 200, Resolution g: 0.001
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 2 variantenProfessional moisture analysers with fast halogen drying technology, made for sophisticated tasks. Very high accuracy and reproducibility. Integrated user management with password protection. 7 inch colour touchscreen with intuitive user guidance. Drying curves and "Good-Bad-ratings", based on individually configurable control limits, are displayed in realtime. 5 automatic and individually definable switch-off criteria. Connectivity with Wi-Fi, LAN, RS232 or USB interface to PCs, FTP servers and printers.The devices offer fully automatic calibration and test functions for the heating and weighing units and are easy to clean.HX204Memory for 300 methods and 3000 results4 drying programs (standard, rapid, gentle, steps)motorized lidHS153 Memory for 99 methods and 3000 results3 drying programs (standard, rapid, gentle)
€13.800,00
pH electrode DGi113-SC | Type: DGi113-SC, Range pH: 0 ... 12, Temperature: 0 ... 60 °C
pH electrode DGi113-SC | Type: DGi113-SC, Range pH: 0 ... 12, Temperature: 0 ... 60 °C
Merk: Mettler-Toledo GmbH (Waagen)For pH measurements and titrations in non-aqueous media. Combined pH glass electrode with movable PTFE sleeve junction and S12 screw cap.A41 glass membrane for improved chemical resistancePlug & play sensor chipARGENTHAL™/LiCl reference systemRefillable reference electrolyte (1 mol/l LiCl)
€675,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DG111-SC, Range pH: 0…14, Temp. range °C: 0…80
pH electrodes for measurements in aqueous and non-aqueous media | Type: DG111-SC, Range pH: 0…14, Temp. range °C: 0…80
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€393,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DG113-SC, Range pH: 0…12, Temp. range °C: 0…60
pH electrodes for measurements in aqueous and non-aqueous media | Type: DG113-SC, Range pH: 0…12, Temp. range °C: 0…60
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€492,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DG115-SC, Range pH: 0…14, Temp. range °C: 0…100
pH electrodes for measurements in aqueous and non-aqueous media | Type: DG115-SC, Range pH: 0…14, Temp. range °C: 0…100
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€508,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi111-SC, Range pH: 0…14, Temp. range °C: 0…80
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi111-SC, Range pH: 0…14, Temp. range °C: 0…80
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€489,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi113-SC, Range pH: 0…12, Temp. range °C: 0…60
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi113-SC, Range pH: 0…12, Temp. range °C: 0…60
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€675,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi114-SC, Range pH: 0…14, Temp. range °C: 0…60
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi114-SC, Range pH: 0…14, Temp. range °C: 0…60
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€665,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi115-SC, Range pH: 0…14, Temp. range °C: 0…100
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi115-SC, Range pH: 0…14, Temp. range °C: 0…100
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€578,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi116-Solvent, Range pH: 0…12, Temp. range °C: 0…100
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi116-Solvent, Range pH: 0…12, Temp. range °C: 0…100
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€639,00
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi117-Water, Range pH: 1…11, Temp. range °C: 0…100
pH electrodes for measurements in aqueous and non-aqueous media | Type: DGi117-Water, Range pH: 1…11, Temp. range °C: 0…100
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 9 variantenDG111-SC: For pH measurement and acid/base titration in aqueous media. With S7 screw cap and detachable cable. ARGENTHAL™ reference system.DGi111-SC: Same as DG111-SC, with Plug & Play functionality.DG113-SC: For pH measurement and titrations in non-aqueous media. With S7 screw cap and detachable cable. Ag/AgCl/LiCl reference system.DGi113-SC: Same as DG113-SC, with Plug & Play functionality and ARGENTHAL™/LiCl reference system and improved chemical resistance.DGi114-SC: For pH measurements and acid/base titrations in clogged and protein or sulfide containing samples. With Plug & Play functionality and ARGENTHAL™ reference system.DG115-SC: For pH measurements and acid/base titrations in aqueous media. Suitable for use in polar solvents, e.g. titration with perchloric acid in acetic acid or with sodium methylate in methanol and other media with low ion concentration. With S7 screw cap and ARGENTHAL™ reference system.DGi115-SC: Same as DG115-SC, with Plug & Play functionality.DGi116-Solvent: Especially suitable for acid/base titrations that require fast response times in non-aqueous media, e.g. TAN/TBN determinations in oils, titrations with perchloric acid, cyclohexylamine and alcoholic HCl, alkalis or Na-Methylate. For determination of epoxy numbers, acid values and saponification numbers, also free fatty acids in polymers, oils/fats and resins. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.DGi117-Water: For pH measurement and acid/base titrations in aqueous solutions of low ion conductivity and low buffer capacity. With integrated Pt1000 temperature sensor. Suitable for measurements in rain-, surface- and drinking water. With Plug & Play functionality and ARGENTHAL™/LiCl reference system.
€895,00
Precision balance LA | Type: LA2002E, Max. load: 2,2 kg, Readability: 10 mg
Precision balance LA | Type: LA2002E, Max. load: 2,2 kg, Readability: 10 mg
Merk: Mettler-Toledo GmbH (Waagen)Beschikbaar in 2 variantenThe precision balance is ideal for simple weighing tasks. The precise load cell delivers fast and reliable results.Bright LCD display with large digitsIntegrated hook for underfloor weighingRS232 interfaceSmall footprintSettings can be locked to prevent changes of the weighing settingsOverload protection secures the balance against heavy loads
€1.295,00

Onze website maakt gebruik van cookies.
Zowel wij en onze derde partij partners maken gebruik van cookies. Sommige zijn strikt noodzakelijk om de site te laten functioneren, maar er bestaan ook optionele cookies.

De noodzakelijke en functionele cookies staan altijd aan. Als je op "alle cookies aanvaarden" klikt accepteer je ook de optionele cookies. Je kan zelf kiezen welke cookies je aan wil zetten via "voorkeuren instellen".

Onze website maakt gebruik van cookies.
Wat zijn cookies? Welke cookies gebruiken we en waarom? Lees meer in ons cookiebeleid

Noodzakelijke cookies

Cookies die onontbeerlijk zijn voor uw bezoek aan de Website en het correct gebruik daarvan

Functionele cookies

Cookies die uw bezoek aan de Website vergemakkelijken en aangenamer maken, onder meer door uw surfervaring te personaliseren.

Performantie cookies

Cookies die informatie verzamelen over uw gebruik van de Website met de bedoeling de inhoud van de Website te verbeteren en aan te passen aan de wensen van de Gebruiker.

Derde partij cookies

Cookies die geplaatst worden door derden die eigen diensten aanbieden via de Website zoals bijvoorbeeld social media, advertenties of videodiensten.