pH probe PHE03 working range 0...14pH, working temperature +5...+60°C
pH probe PHE03 working range 0...14pH, working temperature +5...+60°C
€42,00
pH-sensor 2 Pore F polymer pH-range 0...14 pH, Temperature 0...60°C connection S7 connector
pH-sensor 2 Pore F polymer pH-range 0...14 pH, Temperature 0...60°C connection S7 connector
€159,00
Power supply for 230 VAC for TC301 + TC309
Power supply for 230 VAC for TC301 + TC309
€15,00
Precision handheld instruments P700 series | Type: P700EX, Description: 1 channel, Pt100, explosion protected, only for temperature measurement
Precision handheld instruments P700 series | Type: P700EX, Description: 1 channel, Pt100, explosion protected, only for temperature measurement
Merk: DOSTMANN electronic GmbHBeschikbaar in 11 variantenFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
€580,00
Precision handheld instruments P700 series | Type: P795, Description: 2-channel, Pt100 for inspection equipment monitoring
Precision handheld instruments P700 series | Type: P795, Description: 2-channel, Pt100 for inspection equipment monitoring
Merk: DOSTMANN electronic GmbHBeschikbaar in 11 variantenFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
€890,00
Precision thermometer 2-channel T995 Measuring channel 1/2: PT 100 according to EN60751 Pt100: -200°C... +850°C
Precision thermometer 2-channel T995 Measuring channel 1/2: PT 100 according to EN60751 Pt100: -200°C... +850°C
€1.080,00
Pressure disk light datalogger for print recording
Pressure disk light datalogger for print recording
€1.250,00
PressureDisk data logger up to 140°C
PressureDisk data logger up to 140°C
€1.995,00
Professional thermometer, P4010 1-channel
Professional thermometer, P4010 1-channel
€99,00
Profi digital thermometer P300 -40...+200°C, incl. immersion depth NTC, 130x65x25 mm, incl. ISO-certificate on 0°C/ 60°C
Profi digital thermometer P300 -40...+200°C, incl. immersion depth NTC, 130x65x25 mm, incl. ISO-certificate on 0°C/ 60°C
€90,00
Protec­tion bag for P600/P700-series
Protec­tion bag for P600/P700-series
€49,00
Pt100 immersion probe 300x3mm with handle
Pt100 immersion probe 300x3mm with handle
€73,00

Onze website maakt gebruik van cookies.
Zowel wij en onze derde partij partners maken gebruik van cookies. Sommige zijn strikt noodzakelijk om de site te laten functioneren, maar er bestaan ook optionele cookies.

De noodzakelijke en functionele cookies staan altijd aan. Als je op "alle cookies aanvaarden" klikt accepteer je ook de optionele cookies. Je kan zelf kiezen welke cookies je aan wil zetten via "voorkeuren instellen".

Onze website maakt gebruik van cookies.
Wat zijn cookies? Welke cookies gebruiken we en waarom? Lees meer in ons cookiebeleid

Noodzakelijke cookies

Cookies die onontbeerlijk zijn voor uw bezoek aan de Website en het correct gebruik daarvan

Functionele cookies

Cookies die uw bezoek aan de Website vergemakkelijken en aangenamer maken, onder meer door uw surfervaring te personaliseren.

Performantie cookies

Cookies die informatie verzamelen over uw gebruik van de Website met de bedoeling de inhoud van de Website te verbeteren en aan te passen aan de wensen van de Gebruiker.

Derde partij cookies

Cookies die geplaatst worden door derden die eigen diensten aanbieden via de Website zoals bijvoorbeeld social media, advertenties of videodiensten.