Gas analyzers MAT1100/MAT1200 | Type: MAT1100, Description: with oxygen cell
Gas analyzers MAT1100/MAT1200 | Type: MAT1100, Description: with oxygen cell
Brand: A. Krüss Optronic GmbHAvailable in 2 variantsGas analysers for controlling protective gas packaging. The MAT1100 equipped with an electrochemical oxygen cell measures the oxygen concentration within the range of 0.5 and 35 vol% and with an accuracy of ±0.2 vol%. The MAT1200 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.Sporadic O2 sample checksQuick OperationLow-drift electrochemical oxygen cell (EC)Low-drift carbon non-dispersive infrared sensor (NDIR), model MAT1200Combined O2 and CO2 measurement, model MAT1200Environmental compensated CO2 measurement, model MAT1200
€5.285,00
Gas analyzers MAT1100/MAT1200 | Type: MAT1200, Description: with oxygen cell and NDIR carbon dioxide sensor
Gas analyzers MAT1100/MAT1200 | Type: MAT1200, Description: with oxygen cell and NDIR carbon dioxide sensor
Brand: A. Krüss Optronic GmbHAvailable in 2 variantsGas analysers for controlling protective gas packaging. The MAT1100 equipped with an electrochemical oxygen cell measures the oxygen concentration within the range of 0.5 and 35 vol% and with an accuracy of ±0.2 vol%. The MAT1200 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.Sporadic O2 sample checksQuick OperationLow-drift electrochemical oxygen cell (EC)Low-drift carbon non-dispersive infrared sensor (NDIR), model MAT1200Combined O2 and CO2 measurement, model MAT1200Environmental compensated CO2 measurement, model MAT1200
€6.622,00
Gas analyzers MAT1400/MAT1500 | Type: MAT1400, Description: with zirconia sensor for oxygen
Gas analyzers MAT1400/MAT1500 | Type: MAT1400, Description: with zirconia sensor for oxygen
Brand: A. Krüss Optronic GmbHAvailable in 2 variantsGas analysers for controlling protective gas packaging. The MAT1400 equipped with a zirconium dioxide sensor (ZrO2) measures the oxygen concentration over the entire measurement range between 0 and 100 vol% and with an excellent accuracy of ±0.001 vol%. The MAT1500 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.For high sample throughputFor high O2 concentrationHigh precision with the lowest O2 concentrationsWide measurement rangeDrift-free zirconia sensor (ZrO2)Low-drift non-dispersive infrared sensor (NDIR), model MAT1500Environmental compensated CO2 measurement, model MAT1500
€7.139,00
Gas analyzers MAT1400/MAT1500 | Type: MAT1500, Description: with zirconia sensor for oxygen and NDIR carbon dioxide sensor
Gas analyzers MAT1400/MAT1500 | Type: MAT1500, Description: with zirconia sensor for oxygen and NDIR carbon dioxide sensor
Brand: A. Krüss Optronic GmbHAvailable in 2 variantsGas analysers for controlling protective gas packaging. The MAT1400 equipped with a zirconium dioxide sensor (ZrO2) measures the oxygen concentration over the entire measurement range between 0 and 100 vol% and with an excellent accuracy of ±0.001 vol%. The MAT1500 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.For high sample throughputFor high O2 concentrationHigh precision with the lowest O2 concentrationsWide measurement rangeDrift-free zirconia sensor (ZrO2)Low-drift non-dispersive infrared sensor (NDIR), model MAT1500Environmental compensated CO2 measurement, model MAT1500
€8.489,00

Our website uses cookies.
Both we and our third-party partners use cookies. Some are strictly necessary for the site to function, but there are also optional cookies.

Necessary and functional cookies are always on. If you click "accept all cookies", you also accept the optional cookies. You can choose which cookies you want to enable via "set preferences".

Our website uses cookies.
What are cookies? What cookies do we use and why? Read more in our cookie policy

Necessary cookies

Cookies that are indispensable for your visit to the Website and the correct use thereof

Functional cookies

Cookies that make it easier and more pleasant for you to visit the Website, for example by personalising your browsing experience.

Performance cookies

Cookies that collect information about your use of the Website in order to improve the content of the Website and adapt it to the wishes of the User.

Third-party cookies

Cookies placed by third parties who offer their own services via the Website, such as social media, advertisements or video services.