Please wait

Your message is being sent

An error occurred

Flame Photometers FP8000 series | Type: FP8400, Sample volume ml: 2.5, Description: manual sample feeding
Flame Photometers FP8000 series | Type: FP8400, Sample volume ml: 2.5, Description: manual sample feeding
Brand: A. Krüss Optronic GmbHAvailable in 4 variantsEven the lowest concentrations of alkali and alkaline earth elements in aqueous solutions can be determined cost-effectively and user-friendly. Simultaneous measurement of the elements Na, K, Ca and Li in the laboratory and process analysis (others on request). Thanks to proven measuring methods and modern instrument electronics, the flame photometers achieve precise and reproducible measurement results in a matter of seconds with maximum operational reliability. Suitable for individual measurements, fully automatic measuring operation, continuous operation and use as a process instrument.Economic, user-friendly and durable solution for use in laboratory and process operationSimultaneous measurement of up to four alkaline and alkaline earth elements, depending on model up to 300 measurements per hourMaximum operational safety through intelligent security mechanismsSimple operation through touch screen and intuitive softwareTo use with Popan/Butan (alkaline elements) and Acetylene (alkaline earth elements)Interfaces: 2 x USB, 1 x Ethernet, 1 x RS-232 for printer, FP8500 additionally: Upgrade 4 to 20 mA analogue, passive current interfaceCompliance with international norms and standards
€47.963,50
Flame Photometers FP8000 series | Type: FP8500, Sample volume ml: 2.5, Description: automatic sample feeding
Flame Photometers FP8000 series | Type: FP8500, Sample volume ml: 2.5, Description: automatic sample feeding
Brand: A. Krüss Optronic GmbHAvailable in 4 variantsEven the lowest concentrations of alkali and alkaline earth elements in aqueous solutions can be determined cost-effectively and user-friendly. Simultaneous measurement of the elements Na, K, Ca and Li in the laboratory and process analysis (others on request). Thanks to proven measuring methods and modern instrument electronics, the flame photometers achieve precise and reproducible measurement results in a matter of seconds with maximum operational reliability. Suitable for individual measurements, fully automatic measuring operation, continuous operation and use as a process instrument.Economic, user-friendly and durable solution for use in laboratory and process operationSimultaneous measurement of up to four alkaline and alkaline earth elements, depending on model up to 300 measurements per hourMaximum operational safety through intelligent security mechanismsSimple operation through touch screen and intuitive softwareTo use with Popan/Butan (alkaline elements) and Acetylene (alkaline earth elements)Interfaces: 2 x USB, 1 x Ethernet, 1 x RS-232 for printer, FP8500 additionally: Upgrade 4 to 20 mA analogue, passive current interfaceCompliance with international norms and standards
€51.899,90
Flame Photometers FP8000 series | Type: FP8600, Sample volume ml: 2.5, Description: sample supply via sampler
Flame Photometers FP8000 series | Type: FP8600, Sample volume ml: 2.5, Description: sample supply via sampler
Brand: A. Krüss Optronic GmbHAvailable in 4 variantsEven the lowest concentrations of alkali and alkaline earth elements in aqueous solutions can be determined cost-effectively and user-friendly. Simultaneous measurement of the elements Na, K, Ca and Li in the laboratory and process analysis (others on request). Thanks to proven measuring methods and modern instrument electronics, the flame photometers achieve precise and reproducible measurement results in a matter of seconds with maximum operational reliability. Suitable for individual measurements, fully automatic measuring operation, continuous operation and use as a process instrument.Economic, user-friendly and durable solution for use in laboratory and process operationSimultaneous measurement of up to four alkaline and alkaline earth elements, depending on model up to 300 measurements per hourMaximum operational safety through intelligent security mechanismsSimple operation through touch screen and intuitive softwareTo use with Popan/Butan (alkaline elements) and Acetylene (alkaline earth elements)Interfaces: 2 x USB, 1 x Ethernet, 1 x RS-232 for printer, FP8500 additionally: Upgrade 4 to 20 mA analogue, passive current interfaceCompliance with international norms and standards
€59.456,80
Flame Photometers FP8000 series | Type: FP8700, Sample volume ml: 0.25, Description: diluted sample supply, incl. sampler, diluter, mixer
Flame Photometers FP8000 series | Type: FP8700, Sample volume ml: 0.25, Description: diluted sample supply, incl. sampler, diluter, mixer
Brand: A. Krüss Optronic GmbHAvailable in 4 variantsEven the lowest concentrations of alkali and alkaline earth elements in aqueous solutions can be determined cost-effectively and user-friendly. Simultaneous measurement of the elements Na, K, Ca and Li in the laboratory and process analysis (others on request). Thanks to proven measuring methods and modern instrument electronics, the flame photometers achieve precise and reproducible measurement results in a matter of seconds with maximum operational reliability. Suitable for individual measurements, fully automatic measuring operation, continuous operation and use as a process instrument.Economic, user-friendly and durable solution for use in laboratory and process operationSimultaneous measurement of up to four alkaline and alkaline earth elements, depending on model up to 300 measurements per hourMaximum operational safety through intelligent security mechanismsSimple operation through touch screen and intuitive softwareTo use with Popan/Butan (alkaline elements) and Acetylene (alkaline earth elements)Interfaces: 2 x USB, 1 x Ethernet, 1 x RS-232 for printer, FP8500 additionally: Upgrade 4 to 20 mA analogue, passive current interfaceCompliance with international norms and standards
€62.155,60
Hand spectroscopes | Type: 1501, Labeling: with adjustable split
Hand spectroscopes | Type: 1501, Labeling: with adjustable split
Brand: A. Krüss Optronic GmbHAvailable in 2 variantsHandy and precise. Angle dispersion C -F: 7°. Linear dispersion: 60 mm (direct vision prism of Amici type)Ideal for demonstrations in schools and for:Viewing / observation of emission and absorption spectraControl of the wavelength spectra of gas emission lamps
€229,00
Hand spectroscopes | Type: 1504, Labeling: with adjustable split and wavelength scale (400 to 750nm)
Hand spectroscopes | Type: 1504, Labeling: with adjustable split and wavelength scale (400 to 750nm)
Brand: A. Krüss Optronic GmbHAvailable in 2 variantsHandy and precise. Angle dispersion C -F: 7°. Linear dispersion: 60 mm (direct vision prism of Amici type)Ideal for demonstrations in schools and for:Viewing / observation of emission and absorption spectraControl of the wavelength spectra of gas emission lamps
€413,00
Polarimeter P1000-LED | Type: P1000-LED
Polarimeter P1000-LED | Type: P1000-LED
Brand: A. Krüss Optronic GmbHFor basic lab applications and training, for example the experiment on saccharose inversion.Measurement of optical rotation according to the half-shade principleManual adjustment on the scaleMeasurement results are read through an eyepiece and two noniusesHigh-performance LED with a service life of 100,000 hTube chamber for tubes with a length of up to 220 mmIncludes two measurement tubes with a debubblerLow-maintenance, cost-effective solution
€1.196,00
Polarimeter P3000 | Type: P3000
Polarimeter P3000 | Type: P3000
Brand: A. Krüss Optronic GmbHTechnologically high-quality polarimeter for standard applications for which a measurement accuracy of ±0.01° is sufficient and a temperature control can be omitted. Typically, the P3000 is used in the quality control of food industry.Measurement of optical rotationVery short measurement time of approx. 1 sEasy, menu-driven adjustmentDisplay of measured values in optical rotation or international sugar scaleSuitable tubes for any type of sampleMeasurement up to an optical density of 3.0Temperature measurement with calibratable temperature sensorReliable temperature compensationChemical-resistant measurement tubesCompliance with GMP/GLP, pharmacopoeias [USP, BP, JP, Ph. Eur. (with tempering)], FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST
€8.089,00
Polarimeter P8000 series | Type: P8000, Accuracy: ±0.003° ±0.01 °Z, Description: Without sample temperature control
Polarimeter P8000 series | Type: P8000, Accuracy: ±0.003° ±0.01 °Z, Description: Without sample temperature control
Brand: A. Krüss Optronic GmbHAvailable in 8 variantsPolarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)
€11.989,00
Polarimeter P8000 series | Type: P8000-P, Accuracy: ±0.003° ±0.01 °Z, Description: With Peltier sample temperature control
Polarimeter P8000 series | Type: P8000-P, Accuracy: ±0.003° ±0.01 °Z, Description: With Peltier sample temperature control
Brand: A. Krüss Optronic GmbHAvailable in 8 variantsPolarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)
€13.977,00
Polarimeter P8000 series | Type: P8000-T, Accuracy: ±0.003° ±0.01 °Z, Description: With water temperature control
Polarimeter P8000 series | Type: P8000-T, Accuracy: ±0.003° ±0.01 °Z, Description: With water temperature control
Brand: A. Krüss Optronic GmbHAvailable in 8 variantsPolarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)
€13.377,00
Polarimeter P8000 series | Type: P8000-TF, Accuracy: ±0.003° ±0.01 °Z, Description: With water sample temperature control, flow function
Polarimeter P8000 series | Type: P8000-TF, Accuracy: ±0.003° ±0.01 °Z, Description: With water sample temperature control, flow function
Brand: A. Krüss Optronic GmbHAvailable in 8 variantsPolarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)
€19.509,00

Our website uses cookies.
Both we and our third-party partners use cookies. Some are strictly necessary for the site to function, but there are also optional cookies.

Necessary and functional cookies are always on. If you click "accept all cookies", you also accept the optional cookies. You can choose which cookies you want to enable via "set preferences".

Our website uses cookies.
What are cookies? What cookies do we use and why? Read more in our cookie policy

Necessary cookies

Cookies that are indispensable for your visit to the Website and the correct use thereof

Functional cookies

Cookies that make it easier and more pleasant for you to visit the Website, for example by personalising your browsing experience.

Performance cookies

Cookies that collect information about your use of the Website in order to improve the content of the Website and adapt it to the wishes of the User.

Third-party cookies

Cookies placed by third parties who offer their own services via the Website, such as social media, advertisements or video services.