Please wait

Your message is being sent

An error occurred

pH meters PH CHECK | Type: PH CHECK F
pH meters PH CHECK | Type: PH CHECK F
Brand: DOSTMANN electronic GmbHAvailable in 3 variantsWith fix mounted electrodes, optimised for various applications. For measuring pH value and temperature.One-button calibration function1-3-point calibration availableHold functionClearly readable, split displayAutomatic temperature compensation (ATC)Hold function for current valueHigh degree of protection IP 65Battery life >100 hours in continuous modeBattery status indicatorAutomatic switch-offPH CHECK S: With insertion probe. E.g. suitable for measurements in meat, cheese, ham, semi-solid and solid media.PH CHECK F: With flat electrode. For testing on surfaces and with small sample quantities, e.g. food, leather, paper, skin, agar plates.PH CHECK G: With glass electrode. For general measuring tasks in liquids, especially suitable for aggressive media.Scope of supply: pH measuring instrument, 2 button cells CR2032, container with storage solution
€58,00
pH meters PH CHECK | Type: PH CHECK G
pH meters PH CHECK | Type: PH CHECK G
Brand: DOSTMANN electronic GmbHAvailable in 3 variantsWith fix mounted electrodes, optimised for various applications. For measuring pH value and temperature.One-button calibration function1-3-point calibration availableHold functionClearly readable, split displayAutomatic temperature compensation (ATC)Hold function for current valueHigh degree of protection IP 65Battery life >100 hours in continuous modeBattery status indicatorAutomatic switch-offPH CHECK S: With insertion probe. E.g. suitable for measurements in meat, cheese, ham, semi-solid and solid media.PH CHECK F: With flat electrode. For testing on surfaces and with small sample quantities, e.g. food, leather, paper, skin, agar plates.PH CHECK G: With glass electrode. For general measuring tasks in liquids, especially suitable for aggressive media.Scope of supply: pH measuring instrument, 2 button cells CR2032, container with storage solution
€79,00
pH meters PH CHECK | Type: PH CHECK S
pH meters PH CHECK | Type: PH CHECK S
Brand: DOSTMANN electronic GmbHAvailable in 3 variantsWith fix mounted electrodes, optimised for various applications. For measuring pH value and temperature.One-button calibration function1-3-point calibration availableHold functionClearly readable, split displayAutomatic temperature compensation (ATC)Hold function for current valueHigh degree of protection IP 65Battery life >100 hours in continuous modeBattery status indicatorAutomatic switch-offPH CHECK S: With insertion probe. E.g. suitable for measurements in meat, cheese, ham, semi-solid and solid media.PH CHECK F: With flat electrode. For testing on surfaces and with small sample quantities, e.g. food, leather, paper, skin, agar plates.PH CHECK G: With glass electrode. For general measuring tasks in liquids, especially suitable for aggressive media.Scope of supply: pH measuring instrument, 2 button cells CR2032, container with storage solution
€84,00
pH probe PHE03 working range 0...14pH, working temperature +5...+60°C
pH probe PHE03 working range 0...14pH, working temperature +5...+60°C
€42,00
pH-sensor 2 Pore F polymer pH-range 0...14 pH, Temperature 0...60°C connection S7 connector
pH-sensor 2 Pore F polymer pH-range 0...14 pH, Temperature 0...60°C connection S7 connector
€159,00
Power supply for 230 VAC for TC301 + TC309
Power supply for 230 VAC for TC301 + TC309
€15,00
Precision handheld instruments P700 series | Type: P700, Description: 1 channel, Pt100
Precision handheld instruments P700 series | Type: P700, Description: 1 channel, Pt100
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
€255,00
Precision handheld instruments P700 series | Type: P700EX, Description: 1 channel, Pt100, explosion protected, only for temperature measurement
Precision handheld instruments P700 series | Type: P700EX, Description: 1 channel, Pt100, explosion protected, only for temperature measurement
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
€580,00
Precision handheld instruments P700 series | Type: P705, Description: 2 channel, Pt100
Precision handheld instruments P700 series | Type: P705, Description: 2 channel, Pt100
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
€305,00
Precision handheld instruments P700 series | Type: P710, Description: 1 channel thermocouples Type K, J, L, N, T
Precision handheld instruments P700 series | Type: P710, Description: 1 channel thermocouples Type K, J, L, N, T
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
€205,00
Precision handheld instruments P700 series | Type: P715, Description: 2 channell thermocouples Type K, J, L, N, T
Precision handheld instruments P700 series | Type: P715, Description: 2 channell thermocouples Type K, J, L, N, T
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
€255,00
Precision handheld instruments P700 series | Type: P750, Description: 1 channel, Pt100, moisture, dew piont, flow
Precision handheld instruments P700 series | Type: P750, Description: 1 channel, Pt100, moisture, dew piont, flow
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
€480,00

Our website uses cookies.
Both we and our third-party partners use cookies. Some are strictly necessary for the site to function, but there are also optional cookies.

Necessary and functional cookies are always on. If you click "accept all cookies", you also accept the optional cookies. You can choose which cookies you want to enable via "set preferences".

Our website uses cookies.
What are cookies? What cookies do we use and why? Read more in our cookie policy

Necessary cookies

Cookies that are indispensable for your visit to the Website and the correct use thereof

Functional cookies

Cookies that make it easier and more pleasant for you to visit the Website, for example by personalising your browsing experience.

Performance cookies

Cookies that collect information about your use of the Website in order to improve the content of the Website and adapt it to the wishes of the User.

Third-party cookies

Cookies placed by third parties who offer their own services via the Website, such as social media, advertisements or video services.