Accessories
Analytical balances
Moisture balances
Other balances
Pocket balances
Precision balances
Weights
Analytical balances
Moisture balances
Other balances
Pocket balances
Precision balances
Weights
Buffer solutions
Electrode accessories
Ion selective Electrodes
Paper, chopstick
pH-Electrodes
Portable devices
Redox-Electrodes
Table devices
Electrode accessories
Ion selective Electrodes
Paper, chopstick
pH-Electrodes
Portable devices
Redox-Electrodes
Table devices
Overalls, coats, jackets, trousers
Overshoes, overboots, socks
Surgical masks, beard covers, hoods, sleeves
Overshoes, overboots, socks
Surgical masks, beard covers, hoods, sleeves
Chairs and stools
Gowing benches
Mats and floor coverings
Tables, shelves, trolleys, dispensers
Wardrobes
Gowing benches
Mats and floor coverings
Tables, shelves, trolleys, dispensers
Wardrobes
Components for Extraction
Components for reaction and distillation
Distillation-Accessories
Dropping Funnels
Flasks with NS joint neck
Flat ground flange reaction vessels
Gas wash bottles
Ground joints, attachable
KPG stirrer and bearings
Laboratory reactors
NS joints accessories
Reflux condenser
Standard ground stoppers
Stopcocks and Valves
Tubing adapters
Components for reaction and distillation
Distillation-Accessories
Dropping Funnels
Flasks with NS joint neck
Flat ground flange reaction vessels
Gas wash bottles
Ground joints, attachable
KPG stirrer and bearings
Laboratory reactors
NS joints accessories
Reflux condenser
Standard ground stoppers
Stopcocks and Valves
Tubing adapters
Biobanking
Cryogenic accessories
Cryogenic boxes
Cryogenic racks
Cryogenic storage tanks
Cryogenic tubes
Dewar flasks
Ice machines
Liquid nitrogen-Accessories
Low and Ultra low temperature freezers
Refrigerators and Freezers
Refrigerators and Freezers ex protected
Transport boxes
Cryogenic accessories
Cryogenic boxes
Cryogenic racks
Cryogenic storage tanks
Cryogenic tubes
Dewar flasks
Ice machines
Liquid nitrogen-Accessories
Low and Ultra low temperature freezers
Refrigerators and Freezers
Refrigerators and Freezers ex protected
Transport boxes
Concentration
DNA and RNA isolation
DNA-Electrophoresis
Electroporation
Gel-Documentation
PCR
PCR cabinets
Thermocyclers
DNA and RNA isolation
DNA-Electrophoresis
Electroporation
Gel-Documentation
PCR
PCR cabinets
Thermocyclers
Accessories and reagents
Dissecting sets
Embedding cassettes
Microtoms
Scalpels
Tissue floating baths
Dissecting sets
Embedding cassettes
Microtoms
Scalpels
Tissue floating baths
Cold light sources
Counting chambers
Digital microscopes and cameras
Light microscopes
Microscopy accessories
Slide covers
Slide storage
Slides
Staining racks
Stereomicroscopes
Counting chambers
Digital microscopes and cameras
Light microscopes
Microscopy accessories
Slide covers
Slide storage
Slides
Staining racks
Stereomicroscopes
- 3M Deutschland GmbH
- A J Cope & Son Ltd.
- A&D Instruments Limited
- A. Krüss Optronic GmbH
- Adolf Thies GmbH & Co.KG
- Altmann Analytik GmbH & Co.KG
- Amarell GmbH & Co KG
- Anton Paar Germany GmbH
- ATAGO CO.,LTD
- Bel-Art Products
- BOCHEM Instrumente GmbH
- Bohlender GmbH
- BRAND GMBH + CO.KG
- Büchi Labortechnik GmbH
- Carl Friedrich Usbeck KG
- Cartamundi Deutschland GmbH
- Cole-Parmer Ltd. (Electro)
- Cole-Parmer Ltd. (Jenway)
- Cole-Parmer Ltd. (Stuart)
- Cytiva Europe GmbH
- Deutsche METROHM GmbH & Co.KG
- DOSTMANN electronic GmbH
- DWK Life Sciences GmbH (Duran)
- DWK Life Sciences GmbH (Kimble)
- EUROTIME Uhrenvert. GmbH
- Fritz Arndt Frikmar KG
- GECO Gering
- Glaswarenfabrik Karl Hecht
- Günther Ehle Glasinstrumenten-
- H. & K. Starke GmbH
- HACH LANGE GmbH
- Hahnemühle FineArt GmbH
- Hamilton Bonaduz AG
- Hanhart 1882 GmbH
- Heathrow Scientific LLC
- Hirschmann Laborgeräte GmbH
- IDCP B.V.
- IKA-Werke GmbH & Co.KG
- Industrial Physics Inks
- ISOLAB Laborgeräte GmbH
- J.Engelsmann AG
- Kartell S.p.A.
- Kern & Sohn GmbH
- Knick Elektronische
- Korsing Arbeitsschutz - MEWA
- Köttermann GmbH
- Laborbedarf
- Laborgeräte Süd GmbH & Co.KG
- Lamy Rheology SARL
- Lenz-Laborglas GmbH & Co. KG
- LLG Labware
- Ludwig Schneider GmbH & Co.KG
- Macherey-Nagel GmbH & Co. KG
- Merck KGaA
- Mettler-Toledo GmbH (Prozesst)
- Mettler-Toledo GmbH (Waagen)
- Mettler-Toledo Online GmbH
- MOTIC Deutschland GmbH
- Ohaus GmbH
- Paul Marienfeld GmbH & Co. KG
- Pinselmanufaktur Aulitzky
- Reagecon Diagnostics Ltd.
- Sartorius Lab Instruments
- Scherf Präzision Europa GmbH
- Schorpp Gerätetechnik
- Testo SE & CO KGaA
- TFA Dostmann GmbH & Co.KG
- The Tintometer Limited
- Thermax
- Thermo Elect.LED GmbH (Eutech)
- Thermo Elect.LED GmbH (Orion)
- Thermo Electron GmbH (Haake)
- Tintometer GmbH
- Transport Control
- VITLAB GmbH
- Wagner & Munz GmbH
- Water-i.d. GmbH
- Werner Dorsch GmbH
- Windaus-Labortechnik
- Xylem Analytics Germany (EBRO)
- Xylem Analytics Germany (SI)
- Xylem Analytics Germany (WTW)
Laboratory pH meter 766 | Type: Laboratory pH meter 766
Brand: Knick ElektronischeAvailable in 3 variantsLaboratory pH meter for standard laboratory applicationsGaincheck® performs a complete instrument check. At the touch of a button it not only checks electrical features, but also display and keypad. A short check after power-on automatically reviews efficiency of instrument functions.Drycheck® monitors electrode impedance and alerts to electrode dry-up even in stand-by mode.Sensoface® monitors the electrode performance and provides information on its condition, by evaluating zero point, transconductance and electrode impedanceTrueline® delivers a calibrated analog line recorder signalCalimatic®, which automatically recognises the correct buffer, calibrates safely and easily at the touch of a button. EMC design protects instrument against electromagnetic interference. CE compliant and follows the EMC guidelines. Case made of glass reinforced PA12, stainless steel cover, IP 54 protective system, ready for connection to ZU 6954 attachment stand. Alphanumeric display, 2 x 4 digits, 14 segment LED, character height 13 mm, 3 Sensoface status indicators.Electrode monitoringSensoface®: Evaluates zero point, transconductance, response time and electrode impedance, good/average/poor optical display gives information on electrode condition, can be disabled.Drycheck®: Monitors electrode impedance for dry-up, glass breakage and defective connections also in stand-by mode. Calibration timer monitors calibration intervals.Instrument self-test system:Gaincheck®: Tests electrode and memory data and monitors the measuring circuit and measurement value analysis. Results of all test stages are displayed.Laboratory pH meter 766, includes mains cable and 3 year guarantee.Laboratory pH meter 766 SET A, with mains cable and pH/Pt 1000 SE 101 combination electrode (Plastic, 110 mm).Laboratory pH meter 766 SET B, with mains cable and pH/Pt 1000 SE 100 combination electrode (Glass, 165 mm).Laboratory pH meter 766 | Type: Laboratory pH meter 766
€999,00
Laboratory pH meter 766 | Type: Laboratory pH meter 766 SET A
Brand: Knick ElektronischeAvailable in 3 variantsLaboratory pH meter for standard laboratory applicationsGaincheck® performs a complete instrument check. At the touch of a button it not only checks electrical features, but also display and keypad. A short check after power-on automatically reviews efficiency of instrument functions.Drycheck® monitors electrode impedance and alerts to electrode dry-up even in stand-by mode.Sensoface® monitors the electrode performance and provides information on its condition, by evaluating zero point, transconductance and electrode impedanceTrueline® delivers a calibrated analog line recorder signalCalimatic®, which automatically recognises the correct buffer, calibrates safely and easily at the touch of a button. EMC design protects instrument against electromagnetic interference. CE compliant and follows the EMC guidelines. Case made of glass reinforced PA12, stainless steel cover, IP 54 protective system, ready for connection to ZU 6954 attachment stand. Alphanumeric display, 2 x 4 digits, 14 segment LED, character height 13 mm, 3 Sensoface status indicators.Electrode monitoringSensoface®: Evaluates zero point, transconductance, response time and electrode impedance, good/average/poor optical display gives information on electrode condition, can be disabled.Drycheck®: Monitors electrode impedance for dry-up, glass breakage and defective connections also in stand-by mode. Calibration timer monitors calibration intervals.Instrument self-test system:Gaincheck®: Tests electrode and memory data and monitors the measuring circuit and measurement value analysis. Results of all test stages are displayed.Laboratory pH meter 766, includes mains cable and 3 year guarantee.Laboratory pH meter 766 SET A, with mains cable and pH/Pt 1000 SE 101 combination electrode (Plastic, 110 mm).Laboratory pH meter 766 SET B, with mains cable and pH/Pt 1000 SE 100 combination electrode (Glass, 165 mm).Laboratory pH meter 766 | Type: Laboratory pH meter 766 SET A
€1.172,00
Laboratory pH meter 766 | Type: Laboratory pH meter 766 SET B
Brand: Knick ElektronischeAvailable in 3 variantsLaboratory pH meter for standard laboratory applicationsGaincheck® performs a complete instrument check. At the touch of a button it not only checks electrical features, but also display and keypad. A short check after power-on automatically reviews efficiency of instrument functions.Drycheck® monitors electrode impedance and alerts to electrode dry-up even in stand-by mode.Sensoface® monitors the electrode performance and provides information on its condition, by evaluating zero point, transconductance and electrode impedanceTrueline® delivers a calibrated analog line recorder signalCalimatic®, which automatically recognises the correct buffer, calibrates safely and easily at the touch of a button. EMC design protects instrument against electromagnetic interference. CE compliant and follows the EMC guidelines. Case made of glass reinforced PA12, stainless steel cover, IP 54 protective system, ready for connection to ZU 6954 attachment stand. Alphanumeric display, 2 x 4 digits, 14 segment LED, character height 13 mm, 3 Sensoface status indicators.Electrode monitoringSensoface®: Evaluates zero point, transconductance, response time and electrode impedance, good/average/poor optical display gives information on electrode condition, can be disabled.Drycheck®: Monitors electrode impedance for dry-up, glass breakage and defective connections also in stand-by mode. Calibration timer monitors calibration intervals.Instrument self-test system:Gaincheck®: Tests electrode and memory data and monitors the measuring circuit and measurement value analysis. Results of all test stages are displayed.Laboratory pH meter 766, includes mains cable and 3 year guarantee.Laboratory pH meter 766 SET A, with mains cable and pH/Pt 1000 SE 101 combination electrode (Plastic, 110 mm).Laboratory pH meter 766 SET B, with mains cable and pH/Pt 1000 SE 100 combination electrode (Glass, 165 mm).Laboratory pH meter 766 | Type: Laboratory pH meter 766 SET B
€1.244,00
Laboratory pH meter Knick 765 | Type: Laboratory pH meter 765
Brand: Knick ElektronischeAvailable in 2 variantsWith many safety features making pH measurement easier and more reliable.Fullcheck® automatically checks instrument function from input socket to recorder output. Functional efficiency of the instrument can be documented as part of quality management in accordance with DIN EN ISO 9000 using a test print. Drycheck® monitors electrode impedance and alerts to electrode dry-up, glass breakage and defective connections even in stand-by mode. Sensoface® monitors the electrode performance and gives information on electrode condition, evaluating zero point, transductance, response time, electrode impedance and calibration intervals.Trueline® delivers a calibrated analog recorder signal (electrically isolated). Calimatic® automatically recognises the correct buffer. EMC design protects instrument from electromagnetic interference. The 765 laboratory pH meter complies fully with NAMUR (German committee for measurement and control standards in the chemical industry) EMC recommendations.Temperature compensation is either automatic with a Pt 100 or Pt 1000 sensor or manual. Data can be processed immediately by a computer via standard RS 232 interface. Direct output to a printer is also possible. Large, bright LED display enables simultaneous readout of 2 measured values, such as pH value and temperature.Case made of glass reinforced PA, with non-rusting, stainless steel, IP 54 protection level cover, ready for connection of ZU 6954 electrode stand.Alpahnumerical display, 2 x 4 digits, 14 segment, 13 mm characters, 3 Sensoface status indicators.Interface:RS 232 without control lines, galvanically isolated, printer or computer interface.Printer control:Via serial interface for ZU 0244 or other standard printers, printing at the touch of a button or via print interval timer 0.1 to 999.9 min.Electrode monitoring:Sensoface®:analysis of zero point, transductance, response time and electrode glass impedance, good/average/poor optical display for monitoring electrode condition can be disabled.Drycheck®: Monitors electrode impedance and alerts to electrode dry-up, glass breakage and defective connections even in stand-by mode. Calibration timer monitors calibration interval.Instrument self-test system:Fullcheck®: tests all measurement electronics, including analogue output, segment and keyboard test in diagnostic mode, automatic short test after power-on, QM documentation print-outs according to DIN EN ISO 9000 retrievable in diagnostic mode or via interface (printer).Laboratory pH meter 765, includes mains cable, electrode not included, 3 year guarantee.Laboratory pH meter 765 SET, with electrode statistics (Opt. 347), pH/Pt 1000 SE 100 combination electrode, ZU 6954 attachment stand and ZU 6928 buffer set (no other optional ancillary equipment available).Laboratory pH meter Knick 765 | Type: Laboratory pH meter 765
€1.711,00
Laboratory pH meter Knick 765 | Type: Laboratory pH meter 765 SET
Brand: Knick ElektronischeAvailable in 2 variantsWith many safety features making pH measurement easier and more reliable.Fullcheck® automatically checks instrument function from input socket to recorder output. Functional efficiency of the instrument can be documented as part of quality management in accordance with DIN EN ISO 9000 using a test print. Drycheck® monitors electrode impedance and alerts to electrode dry-up, glass breakage and defective connections even in stand-by mode. Sensoface® monitors the electrode performance and gives information on electrode condition, evaluating zero point, transductance, response time, electrode impedance and calibration intervals.Trueline® delivers a calibrated analog recorder signal (electrically isolated). Calimatic® automatically recognises the correct buffer. EMC design protects instrument from electromagnetic interference. The 765 laboratory pH meter complies fully with NAMUR (German committee for measurement and control standards in the chemical industry) EMC recommendations.Temperature compensation is either automatic with a Pt 100 or Pt 1000 sensor or manual. Data can be processed immediately by a computer via standard RS 232 interface. Direct output to a printer is also possible. Large, bright LED display enables simultaneous readout of 2 measured values, such as pH value and temperature.Case made of glass reinforced PA, with non-rusting, stainless steel, IP 54 protection level cover, ready for connection of ZU 6954 electrode stand.Alpahnumerical display, 2 x 4 digits, 14 segment, 13 mm characters, 3 Sensoface status indicators.Interface:RS 232 without control lines, galvanically isolated, printer or computer interface.Printer control:Via serial interface for ZU 0244 or other standard printers, printing at the touch of a button or via print interval timer 0.1 to 999.9 min.Electrode monitoring:Sensoface®:analysis of zero point, transductance, response time and electrode glass impedance, good/average/poor optical display for monitoring electrode condition can be disabled.Drycheck®: Monitors electrode impedance and alerts to electrode dry-up, glass breakage and defective connections even in stand-by mode. Calibration timer monitors calibration interval.Instrument self-test system:Fullcheck®: tests all measurement electronics, including analogue output, segment and keyboard test in diagnostic mode, automatic short test after power-on, QM documentation print-outs according to DIN EN ISO 9000 retrievable in diagnostic mode or via interface (printer).Laboratory pH meter 765, includes mains cable, electrode not included, 3 year guarantee.Laboratory pH meter 765 SET, with electrode statistics (Opt. 347), pH/Pt 1000 SE 100 combination electrode, ZU 6954 attachment stand and ZU 6928 buffer set (no other optional ancillary equipment available).Laboratory pH meter Knick 765 | Type: Laboratory pH meter 765 SET
€2.261,00
Multi meter Portavo 904 X Multi | Type: 904 X Multi
Brand: Knick ElektronischeThe world's only portable device for liquid analysis with ATEX approval for measurements up to Zone 0/1. Ideal for applications in the process industry. For the first time, Portavo enables direct on-site testing of process measuring points. It is compatible with almost all analog and Memosens process sensors. Memosens sensors with different parameters can be checked without changing the sensor cable.The new MemoLog function allows the user to log calibration data from various Memosens measuring points, which can then be easily transferred to a computer via the standard USB connection. The Paraly SW 112 software enables user-friendly management of all recorded dataA sensor quiver protects the sensor from damage and drying outThe high-performance polymer housing ensures low water absorption and high impact resistanceOver 1000 hours of measurement with a single set of batteries (4 x AA)Data logger with 5000 valuesThe mineral glass display is perfectly readable even after yearsThe world's only portable device for liquid analysis in hazardous locationsMulti meter Portavo 904 X Multi | Type: 904 X Multi
€2.239,00
Multi meters Portavo 907 Multi | Type: 907 Multi Cond, Description: one additional input for analogue conductivity mesurements
Brand: Knick ElektronischeAvailable in 3 variantsThe only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition.The following logging types can be selected:Manual loggingTime-controlled logging at a fixed intervalSignal-controlled logging of measured value and temperatureCombined time and signal-controlled loggingThreshold-controlled logging with pre-triggerThe data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status.User-friendly softwarePortavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help.High-resolution color graphic displayTransflective and sunlight readableLi-ion batteryMicro USB port and Paraly SW 112 softwareA sensor quiver protects the sensor from damage and drying outThe high-performance polymer housing ensures low water absorption and high impact resistanceIntelligent data logger with 10,000 entries and graphical representationMemosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors)The mineral glass display is perfectly readable even after yearsMulti meters Portavo 907 Multi | Type: 907 Multi Cond, Description: one additional input for analogue conductivity mesurements
€1.464,00
Multi meters Portavo 907 Multi | Type: 907 Multi Oxy, Description: one additional input for analogue/optical oxygen mesurements
Brand: Knick ElektronischeAvailable in 3 variantsThe only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition.The following logging types can be selected:Manual loggingTime-controlled logging at a fixed intervalSignal-controlled logging of measured value and temperatureCombined time and signal-controlled loggingThreshold-controlled logging with pre-triggerThe data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status.User-friendly softwarePortavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help.High-resolution color graphic displayTransflective and sunlight readableLi-ion batteryMicro USB port and Paraly SW 112 softwareA sensor quiver protects the sensor from damage and drying outThe high-performance polymer housing ensures low water absorption and high impact resistanceIntelligent data logger with 10,000 entries and graphical representationMemosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors)The mineral glass display is perfectly readable even after yearsMulti meters Portavo 907 Multi | Type: 907 Multi Oxy, Description: one additional input for analogue/optical oxygen mesurements
€1.510,00
Multi meters Portavo 907 Multi | Type: 907 Multi pH, Description: one additional input for analogue pH mesurements
Brand: Knick ElektronischeAvailable in 3 variantsThe only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition.The following logging types can be selected:Manual loggingTime-controlled logging at a fixed intervalSignal-controlled logging of measured value and temperatureCombined time and signal-controlled loggingThreshold-controlled logging with pre-triggerThe data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status.User-friendly softwarePortavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help.High-resolution color graphic displayTransflective and sunlight readableLi-ion batteryMicro USB port and Paraly SW 112 softwareA sensor quiver protects the sensor from damage and drying outThe high-performance polymer housing ensures low water absorption and high impact resistanceIntelligent data logger with 10,000 entries and graphical representationMemosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors)The mineral glass display is perfectly readable even after yearsMulti meters Portavo 907 Multi | Type: 907 Multi pH, Description: one additional input for analogue pH mesurements
€1.310,00
Nominal electrode zero point/electrode slope option 346 for pH meter 765 | Type: 346
Brand: Knick ElektronischeFor use with electrodes having a zero point other than pH 7 and a slope other than 59.2 mV/pH. Nominal electrode zero point and nominal electrode slope is configurable.Nominal electrode zero point/electrode slope option 346 for pH meter 765 | Type: 346
€0,01
pH electrode SE 101-AN | Type: SE 101-AN
Brand: Knick ElektronischepH electrode with plastic shaft and integrated PT1000 temperature sensor. Ideal for pH measurements in environmental and water analysis. With Ag/AgCl reference system and 1 m fixed cable.pH electrode SE 101-AN | Type: SE 101-AN
€227,00
pH electrode SE 101-MS | Type: SE 101-MS
Brand: Knick ElektronischeThe Memosens technology stores the calibration data directly in the sensor head. The inductive transfer of data for the first time lets you take measurements outdoors without having to worry about interference due to rain or contamination.pH electrode SE 101-MS | Type: SE 101-MS
€290,00
Copyright © 2024 - Achrom nv - BE 0445.025.508 | General terms | Cookiebeleid | Privacybeleid | Handcrafted by CrayonCru®