OPTIMA® 225 capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
OPTIMA® 225 capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 7 variants50% cyanopropylmethyl - 50% phenylmethylpolysiloxaneUSP G7 / G19middle polar phaserecommended for fatty acid analysessimilar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, 007-225, BP225max. temperature for isothermal operation: 260°C, max. temperature for short isotherms in a temperature programme: 280°C
€1.125,00
Optima® 5 Amine GC capillary columns for amine separation | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Film thickness µm: 1.00
Optima® 5 Amine GC capillary columns for amine separation | Int. diam. mm: 0.25, Outer diam. mm: 0.4, Film thickness µm: 1.00
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 3 variantsespecially deactivated for the analysis of polyfunctional amines such as ethanolamines, amino-functionalised diols and similar compounds, which are important base materials in industrial chemistry, and shows strong tailing on standard-deactivated columns; similar phases: Rtx-5 Amine, PTA-5; USP G27 / G36; improved linearity for analyses of active components at trace levels: no amine absorptions even for aliphatic and aromatic amines at concentrations of 100 pg/peak; tested with the Optima® Amine test mixture, which among others also contains diethanolamine and propanol-pyridine (this test mixture is supplied with each column). Max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°C.
€680,00
OPTIMA® 5 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Length m: 50
OPTIMA® 5 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Length m: 50
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 58 variants5% phenyl - 95% dimethylpolysiloxane USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films
€1.130,00
OPTIMA® 5 MS Accent capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.50
OPTIMA® 5 MS Accent capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.50
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 11 variantssilarylene phaseWith polarity similar to a 5 % diphenyl -95 % dimethylpolysiloxane phase.USP G27, G36Lowest column bleed, nonpolar phase, ideal for ion trap and quadrupol MS detectors solvent rinsing for removal of impurities applicableApplication areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analysessimilar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MSMax. temperature for isothermal operation: 340 °C,Max. temperature for short isotherms in a temperature programme: 360 °Cfor cloumns with film thicknesses > 5.5 µm the max. temperatures are 320 and 340 °C
€815,00
OPTIMA® 5 MS capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Length m: 50
OPTIMA® 5 MS capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Length m: 50
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 10 variants5% diphenyl - 95% dimethylpolysiloxanenonpolar phase with low bleeding, deal for GC/MS and ECD applications and general analyses at trace level perfect inertness for basic compounds.Similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS.max. temperature for isothermal operation: 340°C, max. temperature for short isotherms in a temperature programme: 360 °C
€1.210,00
Optima® 624 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 3.0
Optima® 624 capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 3.0
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 8 variants6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneUSP G43medium polar phaserecommended for environmental analysessimilar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°C
€730,00
Optima® 624 LB capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 1.8
Optima® 624 LB capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 1.8
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 2 variants6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneUSP G 43medium polar phaselow bleed columns for halogenated hydrocarbons, volatiles, aromatic compounds, solvents etc.similar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°C
€1.210,00
Optima® FFAP capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
Optima® FFAP capillary columns for GC | Int. diam. mm: 0.32, Outer diam. mm: 0.5, Film thickness µm: 0.25
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 14 variantspolyethylene glycol 2-nitroterephthalateclose equivalent USP G25 / G35polar phaserecommended for FAME, free carboxylic acidssimilar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukolfor columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp.
€1.060,00
Optima® WAX capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 1.00
Optima® WAX capillary columns for GC | Int. diam. mm: 0.53, Outer diam. mm: 0.8, Film thickness µm: 1.00
Brand: Macherey-Nagel GmbH & Co. KGAvailable in 15 variantspolyethylene glycol 20000 daltonsUSP G16polar phaserecommended for solvent analysis and alcoholssuitable for aqueous solutionssimilar phases: Premabond® CW 20 M , DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax, 007-CW, BP20, AT-Wax, ZB-WaxMax. temperature for isothermal operation 240°C, max. temperature for short isotherms in a temperature programme: 250°C,for 0.53 mm ID columns the max. temperatures are 220 and 240°C, resp.
€730,00
Preventative Maintenance | Description: Compressor Kit 230V - G2/G3/G4/G7 option 1, Change interval: 12 months
Preventative Maintenance | Description: Compressor Kit 230V - G2/G3/G4/G7 option 1, Change interval: 12 months
Brand: Parker Hannifin GmbHAvailable in 9 variants
€1.155,66
Preventative Maintenance | Description: Desiccant cartridge, Change interval: As required*
Preventative Maintenance | Description: Desiccant cartridge, Change interval: As required*
Brand: Parker Hannifin GmbH* 20H Continuous operation approx 6 to 7 months* 40H Continuous operation approx 4 to 5 months* 60H Continuous operation approx 2 to 3 months
€191,05
Preventative Maintenance | Description: Fan PM Kit, 230V - all models, Change interval: 24 Months
Preventative Maintenance | Description: Fan PM Kit, 230V - all models, Change interval: 24 Months
Brand: Parker Hannifin GmbHAvailable in 3 variants
€118,42

Our website uses cookies.
Both we and our third-party partners use cookies. Some are strictly necessary for the site to function, but there are also optional cookies.

Necessary and functional cookies are always on. If you click "accept all cookies", you also accept the optional cookies. You can choose which cookies you want to enable via "set preferences".

Our website uses cookies.
What are cookies? What cookies do we use and why? Read more in our cookie policy

Necessary cookies

Cookies that are indispensable for your visit to the Website and the correct use thereof

Functional cookies

Cookies that make it easier and more pleasant for you to visit the Website, for example by personalising your browsing experience.

Performance cookies

Cookies that collect information about your use of the Website in order to improve the content of the Website and adapt it to the wishes of the User.

Third-party cookies

Cookies placed by third parties who offer their own services via the Website, such as social media, advertisements or video services.